SamplingPoint
Attributes
Attribute Code |
Attribute Name |
SQL DB Data Type |
ReportNet3 Data Type |
Properties |
Code list |
Related table(s) |
In Reporting |
|---|---|---|---|---|---|---|---|
SPO_01 |
CountryCode |
varchar(2) |
string |
PK |
|||
SPO_02 |
AssessmentMethodId |
varchar(50) |
string |
PK |
ComplianceAssessmentMethod |
||
SPO_03 |
SamplingPointReferenceId |
varchar(32) |
string |
||||
SPO_04 |
PollutantId |
int |
numeric |
||||
SPO_05 |
StationEoICode |
varchar(10) |
string |
MeasurementStation |
|||
SPO_06 |
Country |
varchar(20) |
string |
N |
|||
SPO_07 |
SamplingPointStatus |
bit |
boolean |
N |
|||
SPO_08 |
Pollutant |
varchar(50) |
string |
N |
|||
SPO_09 |
Deletion |
bit |
boolean |
N |
Note
Country, SamplingPointStatus, Pollutant and Deletion are Reference attributes without a corresponding attribute in the reporting data model.
Attribute details
SPO_01 - CountryCode
Content
Country or territory ISO2 code.
In Reporting
SPO_02 - AssessmentMethodId
Content
Identifier of the assessment method (sampling point), given by data provider.
Remarks
A sampling point (AssessmentMethodId) can be closed (set as inactive) by ending the ProcessId (specifying ProcessActivityEnd).
The same sampling point (AssessmentMethodId) can be re-open (also with the same ProcessId) by adding new record with new ProcessActivityBegin.
In Reporting
SPO_03 - SamplingPointReferenceId
Content
Reference identifier of the assessment method (sampling point), either re-used or given by data provider following strict rules.
Remarks
Following rules of SPO reference code, unique within CountryCode reported and it can serve as reference code list.
In Reporting
SPO_04 - PollutantId
Content
Code of the air pollutant being measured, as per Data Dictionary standards.
Remarks
Only one for the same AssessmentMethodId/SamplingPointReferenceId.
In Reporting
SPO_05 - StationEoICode
Content
EoI (Exchange of Information) code of the air quality measurement station, as in AirBase, either re-used or given by data provider following strict rules.
Code list / reference
There will be no specific code list in Data Dictionary but the Station table in reference data flow will serve as code list for AirQualityStationEoICode values.
Remarks
StationEoICode must be always provided and cannot be modified.
Station will become inactive if all sampling points in that station are inactive.
The same Station can become active again if there are new active sampling points or existing sampling points become active again.
It will be cross-checked against Station table.
In Reporting
SPO_06 - Country
Content
Name of the country.
In Reporting
N - No corresponding reporting attribute.
SPO_07 - SamplingPointStatus
Content
Indicator wheter the SPO is operational or not.
In Reporting
N - No corresponding reporting attribute.
SPO_08 - Pollutant
Content
Name of the air pollutant being measured, as per Data Dictionary standards.
In Reporting
N - No corresponding reporting attribute.
SPO_09 - Deletion
Content
Flag to indicate that this element must be deleted..
In Reporting
N - No corresponding reporting attribute.